(F/UTP)Data Transmission Cable for Local Networks
with central-element and shield, Category 6
Conductor materialBare, solid copper conductor, Ø 0,55mm
(AWG 24/1)
core insulation SFS Polyethylen
Overall shielding aluminium foil with a tinned drain wire Ø 0,5mm
screen tinned copper braiding
layer plastic foil
plastic laminated aluminium foil
PVC-sheath or with halogen free sheath
Standards: ISO/IEC 11801 2.Edition
EN 50173-1
TIA/EIA 568-B.2
IEC 61156-5
EN 50288-5-1
Technical data:
Temperature range -0°C TO +60°C (moved)
Loop impedance 19,0 [Ohm/100m]
Capacity max. 50[nF/km]
Nom. Velocity of propagation NVP nom. 77,0
Attenuation 100,0+/- 22[Ohm]
couplingresistance 10[mOhm/m]
Capacity coupling 150[pF/100m]
Insualtion resistance >5[GOhm/km]
Test voltage at 50 Hz 700[VAC]
Application:
In the horizontal cabling as an installation for laying cable in cable channels and pipes inside of telecommunications equipment and data systems to 350 Mhz. Installation is very easy because of a central element (cross) no individual shield is required.
Usable for: 10Base-T, 100 Base-T, 1000 Base-T, CDDI/TPDDI, ISDN, ATM 155 Mbit/s, TP-PMD 125 Mbit/s, Token Ring 4/16 Mbit/s.